HOME / PRODUCTS / Power Strip / Germany Type Power Strip

Germany Type Power Strip Custom

Germany Type Power Strip Supplier

Germany Type Power Strip is designed for high-standard electrical needs, with a solid high-quality material shell to ensure excellent durability and impact resistance. Each socket hole has passed rigorous high-voltage testing, meets Germany's strict safety regulations, and is equipped with a child protection sheet to prevent accidental electric shock. Its stable plug-in contact design provides stable power transmission and is suitable for use in home, office and industrial environments. Our efficient assembly team ensures that each socket has stable performance and long service life, which is a perfect combination of safety and efficiency.

About Lianou CIXI LIANOU ELECTRICAL APPLIANCE CO., LTD.

Cixi Lianou Electrical Appliance Co., Ltd. is China Germany Type Power Strip Supplier and Wholesale Germany Type Power Strip Company, specializes in the production of PVC raw materials, power cords, injection-molded plugs, plug cords, extension cords, and cable reels. Integrating design, development, production, sales, and service, it is a key enterprise in Zhejiang Province. Occupying 5,000 square meters, it specializes in the production of European power cords, PVC power cords, and plugs and sockets certified by famous countries. Its products are widely used in a variety of small appliances, electronic products, and household appliances. The company has over 20 experienced, skilled, and innovative engineers and quality management personnel, and over 100 employees. Equipped with a complete set of advanced production equipment, the company has an annual production capacity of 10 million units and is striving to increase capacity to meet growing market demand. For many years, the company has implemented modern corporate management and regularly provides employee training to ensure consistent quality. Since its inception, the company has actively adopted national and international standards for its production, and holds VDE, NF, GS, S, and CE certifications. PVC raw material - polyvinyl chloride has REACH, ROHS1.0, ROHS2.0, PAHS and other environmental protection certificates. With a responsible attitude towards society, the company fully advocates environmental protection. All products comply with EU ROHS, REACH, PAHS and other environmental protection requirements. The products are exported to Europe, Australia, the Middle East, South Africa and Northeast Asia. The company's perfect service and strict quality management have won praise from many customers.

  • 2005

    Founded in

  • 5000+

    Covered area

  • 1000+

    Annual production capacity

  • 100+

    Number of employees

News Center

  • Industry News 2026-05-29

    No — you generally cannot safely plug an American power strip directly into a European wall outlet without additional equipment. The core reason is a fundamental electrical incompatibility: the United States uses 120V/60Hz electricity, while Europe operates on 220–240V/50Hz. Plugging a standard US power strip into a Eu...

    View More
  • Industry News 2026-05-21

    The short answer: a standard North American power strip will NOT work safely in Europe without a voltage converter. Europe operates on 220–240V AC at 50Hz, while North America runs on 110–120V at 60Hz. Plugging a non-dual-voltage power strip into a European outlet without proper conversion can destroy your devices — o...

    View More
  • Industry News 2026-05-14

    US power strips can be physically connected to European outlets using a plug adapter, but doing so carries serious risks and is generally not recommended without proper precautions. The core problem is voltage: the US runs on 110–120V while Europe uses 220–240V. Plugging a standard American power strip into a European...

    View More

Contact Us Now

Germany Type Power Strip Industry knowledge

I. Technical Specifications and Certification of Germany Type Power Strips
The core basis of Germany Type Power Strips is the DIN standard (Deutsches Institut für Normung) and the VDE standard (Verband der Elektrotechnik, Elektronik und Informationstechnik). These standards provide detailed specifications for the electrical performance, mechanical structure, and safety requirements of power strips.

Plug and Socket Specifications
Germany Type Power Strips use a Type F socket (CEE 7/4), commonly known as a "Schuko socket." It features two round pins (19mm center spacing, 4.8mm diameter) and grounding clips on both sides. The rated voltage is 230V, the rated current is typically 16A, and the frequency is 50Hz. The plug must comply with DIN 49440 and DIN 49441 standards to ensure compatibility with the socket.

Electrical Performance Requirements
Insulation resistance: The insulation resistance between live parts and the housing must be greater than 100MΩ (test voltage 500V DC).

Dielectric Strength: Withstands a 4000V AC/min withstand voltage test without breakdown or flashover.

Temperature Rise Limit: The terminal temperature must not exceed 45K during extended operation at rated current.

Safety Certification
The product must be VDE certified (such as VDE 0620-1) and bear the CE mark (in compliance with the EU Low Voltage Directive 2014/35/EU). In some scenarios, it must also meet the environmental requirements of RoHS (2011/65/EU) and REACH regulations.

II. Materials and Manufacturing Process
Germany Type Power Strips have extremely strict material selection and process control to ensure long-term reliability and safety.

Conductor Materials
Power cords typically use oxygen-free copper (OFC) conductors, with a cross-sectional area that matches the rated current (e.g., ≥1.5mm² for 16A applications). Copper purity must be ≥99.9% to ensure low resistance and high conductivity.

Insulation and Jacketing
PVC (polyvinyl chloride) is a commonly used insulation material and must meet the VDE 0282 standard. It must have a heat resistance rating of ≥90°C (e.g., PVC T90) and flame retardancy that meets UL94 V-0. Some high-end products use halogen-free materials (e.g., TPE) to reduce the release of toxic gases in the event of a fire.

Plug and Housing Injection Molding
Plug housings are typically made of high-impact PC (polycarbonate) or ABS engineering plastics and must pass the ball pressure test (no deformation at 125°C) and the glow-wire test (no ignition at 850°C). Cixi Lianou Electrical Appliance Co., Ltd. uses precision injection molding to ensure that plug dimensions meet DIN tolerances (±0.1mm).

Internal Connection Structure
The socket springs are nickel-plated with phosphor bronze to ensure spring contact and corrosion resistance.

Solder points must pass a pull test (>50N) and a micro-ohm resistance test (<5mΩ).

A protective door design is mandatory to prevent single-pole insertion (compliant with IEC 60884-2-5).

III. Application Scenarios and Compatible Devices
Germany Type Power Strips are suitable for a wide range of applications, and the appropriate IP rating (IP code) should be selected based on the environment:

Home and Office
Basic Power Strip (IP20): For use in dry environments, connecting computers, lamps, and other devices.

Child-Resistant (IP44): Equipped with a reinforced safety door and concealed sockets.

Industrial Environment
High-Protection-Rated Power Strip (IP67): Dust- and water-resistant, suitable for use in workshops and laboratories.

Models with Filtering and Surge Protection: Suppress power spikes and protect precision instruments.

Special Applications
Medical-Grade Power Strip (compliant with IEC 60601-1): Reinforced insulation and leakage current control (<0.1mA).

Outdoor Power Strip (IP54 and above): Made of UV-resistant materials, suitable for temporary power supply applications.

IV. Safety Design and Protection Features
The safety design of Germany Type Power Strips goes beyond basic requirements and includes multiple protection mechanisms:

Overload Protection
Some models feature a built-in thermal fuse or bimetallic circuit breaker that automatically disconnects power when the current exceeds 125% of the rated value.

Electric Shock Protection
Ground Continuity: The ground resistance must be <0.1Ω to ensure rapid tripping of the circuit breaker in the event of a current leakage.

Safety Door Mechanism: A mechanical interlock prevents children from accidentally inserting foreign objects.

Creep Distance and Clearance: ≥3mm between live parts (according to Pollution Degree II).

Fire and Heat Resistance: The outer casing must pass the GLOW-WIRE test (no ignition after contact at 750°C for 30 seconds), and the internal materials must meet the needle flame test (IEC 60695-11-5).

Mechanical Durability: The plugging and unplugging life must pass the 10,000 cycle test (IEC 60884-1), with an insertion and unplugging force maintained within the 10-50N range.